Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(5): 054101, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35649790

RESUMO

We developed an integrated device composed of a single-probe Electroencephalogram (EEG) and Charge Coupled Device (CCD) based motion sensors for objective measurement of Attention-deficit Hyperactivity Disorder (ADHD). While the measurement of attention-deficit hyperactivity disorder (MAHD) relies on the EEG signal for the assessment of attention during a given structured task, the CCD sensor depicts the movement pattern of the subjects engaged in a continuous performance task. A statistical analysis of attention and movement patterns was performed, and the accuracy of completed tasks was analyzed using indigenously developed software. The device with the embedded software is intended to improve certainty with criterion E. We used the EEG signal from a single-channel dry sensor placed on the frontal lobe of the head of the subjects (3-5 year old pre-schoolers). During the performance of the task power for delta and beta, EEG waves from the subjects are found to be correlated with relaxation and attention/cognitive load conditions. While the relaxation condition of the subject hints at hyperactivity, a more direct CCD-based motion sensor is used to track the physical movement of the subject engaged in a continuous performance task. We used our indigenously developed software for statistical analysis to derive a scale for the objective assessment of ADHD. We also compared our scale with clinical ADHD evaluations and found a significant correlation between the objective assessment of the ADHD subjects and the clinician's conventional evaluation. MAHD, the integrated device, is supposed to be an auxiliary tool to improve the accuracy of ADHD diagnosis by supporting greater criterion E certainty.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade , Transtorno do Deficit de Atenção com Hiperatividade/diagnóstico , Transtorno do Deficit de Atenção com Hiperatividade/psicologia , Pré-Escolar , Eletroencefalografia , Humanos
2.
Phys Chem Chem Phys ; 24(10): 6176-6184, 2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35229087

RESUMO

The potentiality of Förster resonance energy transfer (FRET) for studying molecular interactions inside biological tissues with improved spatial (Angström) and temporal (picosecond) resolution is well established. On the other hand, the efficacy of diffuse reflectance spectroscopy (DRS) that uses optical radiation in order to determine physiological parameters including haemoglobin, and oxygen saturation is well known. Here we have made an attempt to combine diffuse reflectance spectroscopy (DRS) with picosecond-resolved FRET in order to show improvement in the exploration of molecular contacts in biological tissue models. We define the technique as ultrafast time-resolved diffuse reflectance spectroscopy (UTRDRS). The illuminated photon of the fluorophore from the surface of the tissue-mimicking layers carries the hidden information of the molecular contact. In order to investigate the validation of the Kubelka-Munk (KM) formulism for the developed UTRDRS technique in tissue phantoms, we have studied the propagation of incandescent and picosecond-laser light through several layers of cellulose membranes. While picosecond-resolved FRET in the diffuse reflected light confirms the hidden nano-contact (4.6 nm) of two different dye layers (8-anilino-1-naphthalenesulfonic acid and Nile blue), high-resolution optical microscopy on the cross-section of the layers reveals the proximity and contacts of the layers with limited spatial resolution (∼300 nm). We have also investigated two biologically relevant molecules, namely carboxyfluorescein and haemoglobin, in tissue phantom layers in order to show the efficacy of the UTRDRS technique. Overall, our studies based on UTRDRS in tissue mimicking layers may have potential applications in non-invasive biomedical diagnosis for patients suffering from skin diseases.


Assuntos
Transferência Ressonante de Energia de Fluorescência , Luz , Transferência Ressonante de Energia de Fluorescência/métodos , Corantes Fluorescentes , Hemoglobinas , Humanos , Análise Espectral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...